183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)
  • Load image into Gallery viewer, 183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)

183 kW Prime Power Volvo Diesel Generator (600V Three Phase 60Hz)

Regular price
$44,849.99
Sale price
$44,849.99
Regular price
$50,000.00
Sold out
Unit price
per 
Shipping calculated at checkout.

*All Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement*

 

1-year/1000 hours Warranty with Free parts and Service Guidance!

 

Master industrial generator sets are fully integrated power generation systems that provide optimum performance, dependability, and versatility for standby and prime power applications.

 

Powered by Volvo engine, Stamford alternator, and SmartGen control panel

  

Prime power

This rating is for continuous electrical power supply (at variable load). There is no limit on the annual hours of operation, and 10% overload power can be supplied for 1 hour in 12.

Standby power

This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted.

Features:

Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load, 100% load, 110% load and the checking and proving of all control and safety shut-down functions

24V DC start motor

Equipped 24V high-performance maintenance-free lead-acid starting batteries 

Equipped with industrial silencer and flexible exhaust hose

Designed to Comply with ISO8528/GB2820

 

Volvo Engine Technical Data:

Model: TAD753GE

Manufacturer: Volvo Penta

Number of Cylinders: 6 Cylinders, Vertical In line

Cycle: 4 Stroke

Aspiration: Wastegate Turbocharger

Bore x Stroke: 108 mm x 130 mm

Displacement: 7.15 L

Compression Ratio: 18:1

Prime Power with Fan / Speed: 192 kW / 1800 rpm

Standby Power with Fan / Speed: 213 kW / 1800 rpm

Speed Governor: ECM

Cooling System: Forced Liquid Cooling Cycle

Steady Speed Drop: ≤ 1%

Total Lubrication System Capacity: 34 L

Fuel Consumption at 100% Load: 217 g/kW h

Starter Motor: DC24V

Alternator: DC24V

 

Stamford Alternator Technical Data

Alternator Model: UCI274G

Continuous Power: 183 kW

Frequency / Speed: 60Hz / 1800rpm

Exciter Type: Single Bearing, Brushless, Self-excited

Power Factor: 0.8 

Voltage Adjust Range: ≥ 5%

Voltage Regulation NL-FL: ≤ ±1%

Insulation Grade: H

Protection Grade: IP23

Phase: 3

 

CSA Approved

 

SmartGen Control Panel Technical Data:

Model: HGM6110CAN

 

The control module gives digital readouts of:

Generator voltage

Output Frequency

Engine speed

Battery voltage

Engine hours run

 

The control module has indicators for failure information: 

Overspeed/Underspeed

Emergency stop

Low oil pressure

High water temperature

Failure to start

Battery charger failure

 

Automatic shutdown occurs under:

Low engine oil pressure 

High engine water temperature

Overspeed/Underspeed 

Failure to start after three attempts

 